ASCP BOC Specialist in Chemistry (SC) Examination Practice Test

The ASCP BOC Specialist in Chemistry (SC) Examination practice page addresses advanced clinical chemistry concepts used to evaluate laboratory results and investigate analytical problems. Its question bank samples topics such as assay interference, quality control, acid-base calculations, renal and glycemic markers, enzyme results, and specimen-related effects.

Exam overview

Exam providerASCP Board of Certification
Exam codeSC
CategoryMedical Laboratory

About the ASCP BOC Specialist in Chemistry (SC) Examination Exam

Chemistry practice involves judging whether a result reflects a patient's condition or an analytical or preanalytical problem. Questions may ask you to interpret Levey-Jennings control patterns and choose an immediate response, assess dilution studies when interference is suspected, or recognize how biotin can affect susceptible immunoassays. Other scenarios involve calculating the anion gap, understanding the limits of creatinine-based eGFR, and comparing biomarkers such as lipase and amylase. Specimen handling also matters: delayed cell separation can alter analyte concentrations, while urine storage can change measured properties. These tasks connect measurement principles, quality systems, specimen integrity, and clinical interpretation—the reasoning needed to evaluate chemistry results before they inform patient care.

Sample Practice Questions

Review a selection from this exam's published US Practice Tests practice bank.

Question 1

A laboratory prepares a dilution series of a patient specimen to investigate a suspected interfering substance. The measured analyte concentration, after correction for dilution, is consistent across the dilutions. What does this finding generally support?

  1. AThe assay is behaving approximately proportionally over the tested dilution range
  2. BThe analyte is necessarily absent from the original specimen
  3. CThe calibrator has been assigned the wrong units
  4. DThe specimen must contain a high concentration of bilirubin
Show answerCorrect answer: A

When corrected results agree across serial dilutions, the assay response is generally consistent with proportionality over that range. Nonparallel or inconsistent corrected results may suggest nonlinearity or interference, though dilution studies do not identify every cause.

Question 2

A laboratory uses Levey-Jennings charts to monitor two levels of control material. One control result exceeds the mean by more than three standard deviations. What is the usual immediate quality-control response?

  1. AAccept the run because only one control level is affected
  2. BReject the run and investigate before reporting patient results
  3. CShift the control mean to include the result
  4. DRepeat patient testing only if a clinician requests it
Show answerCorrect answer: B

A control result beyond three standard deviations is commonly treated as a rejection signal under Westgard-style quality-control rules. The run should be assessed for analytical problems, and patient results should not be released until the issue is resolved according to laboratory procedure.

Question 3

A patient has a high anion gap metabolic acidosis. Which calculation is conventionally used to estimate the anion gap when potassium is omitted?

  1. ASodium − (chloride + bicarbonate)
  2. BChloride − (sodium + bicarbonate)
  3. CBicarbonate − (sodium + chloride)
  4. DSodium + chloride + bicarbonate
Show answerCorrect answer: A

The commonly used anion gap calculation without potassium is sodium minus the sum of chloride and bicarbonate. The result can help categorize metabolic acidosis, but interpretation should account for the laboratory's methods and factors such as albumin concentration.

Question 4

A patient taking high-dose biotin has thyroid immunoassay results that do not fit the clinical presentation. In assays that use streptavidin-biotin binding, what is a reasonable laboratory consideration?

  1. ABiotin interference may alter results, with the direction depending on assay design
  2. BBiotin invariably causes every immunoassay result to be falsely increased
  3. CBiotin selectively destroys thyroid hormones in the specimen
  4. DBiotin affects only measurements made by ion-selective electrodes
Show answerCorrect answer: A

High circulating biotin can interfere with assays that rely on streptavidin-biotin interactions. The effect and direction vary with assay format, so clinicians and the laboratory should consider exposure and assay-specific guidance.

Question 5

A laboratory reports an estimated glomerular filtration rate (eGFR) calculated from serum creatinine. Which statement best describes the result?

  1. AIt is a direct measurement of filtration using a measured filtration marker
  2. BIt is an estimate derived from creatinine and patient variables, and can be less reliable when kidney function is changing rapidly
  3. CIt is independent of age and other demographic variables in every equation
  4. DIt measures renal blood flow rather than filtration
Show answerCorrect answer: B

Creatinine-based eGFR is calculated from serum creatinine and variables specified by the equation, rather than being a direct measurement of filtration. Because serum creatinine may lag behind acute changes in kidney function, eGFR estimates are less reliable when concentrations are not at steady state.

Question 6

Which serum analyte is most directly used to assess the adequacy of a patient's long-term glycemic control over roughly the preceding two to three months?

  1. AFructosamine
  2. BHemoglobin A1c
  3. CFasting insulin
  4. DC-peptide
Show answerCorrect answer: B

Hemoglobin A1c reflects the proportion of hemoglobin that has undergone glycation over the lifespan of circulating erythrocytes, so it provides an estimate of average glycemia over approximately two to three months. Conditions affecting red-cell lifespan can alter interpretation.

Question 7

A urine specimen is left at room temperature for several hours before analysis. Which change is most likely to occur if it is not preserved or refrigerated?

  1. ABacterial growth may increase urine pH
  2. BUrine glucose will reliably increase because bacteria synthesize glucose
  3. CUrine ketones will become more stable
  4. DUrine bilirubin will be protected from light
Show answerCorrect answer: A

Bacterial proliferation can occur in an unrefrigerated urine specimen. Urea-splitting organisms may increase pH, and other analytes and formed elements can also change, which is why timely testing or appropriate storage is important.

How to use this practice test

The free practice bank contains 50 questions; each session presents up to 20 questions selected at random. Complete a session to see your results, then use missed or uncertain items to identify concepts for targeted review, such as assay interference, quality control, or preanalytical specimen effects.

Preparation tips

  • For Levey-Jennings scenarios, distinguish a single control result beyond three standard deviations from patterns that suggest other control-rule violations, and identify the appropriate immediate response.
  • Practice the anion gap calculation with potassium omitted, and explain what a high result indicates in metabolic acidosis.
  • Review how streptavidin-biotin assay designs can be affected by high-dose biotin, including why results may conflict with the clinical picture.
  • Compare serum lipase with amylase in suspected pancreatitis, and review the time period represented by hemoglobin A1c.
  • Trace how delayed serum separation and unrefrigerated urine storage can affect results; connect each change to specimen handling.